ANALOGUE INPUT PANEL METERS
Actualizado: 2024-01-04
Universal panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso Intuitive and easy programming (high flexibility)
o 016 points scaling for linearisation
o Programmable function keys/user inputs
o Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...020 mA or 0...10 V
- 2 or 4 set-points with relay outputs
- RS-232, RS-485, USB or fieldbus capabilities
- NEMA 4X / IP67 (transparent protection cover - Option \"COVER PAX\")
- Desktop or industrial steel housing
- Rail DIN adaptor
DISPLAY FOR ROTARY TORQUE SENSOR
Actualizado: 2024-01-04
The DISP-60 is a display specially designed to be connected with a non-contact rotary torque sensor of the SENSY 60000 series.o 1 torque sensor input 0...10 V
o 1 angle encoder input (A/B) or speed sensor input (A)
o 2 x digital input
o 2 x relay output
o USB interface (2.0 HID - Windows ® compatible software included)
o SD card slot (SD / SD HC)
o Acquisition interval: 10 ms...1 h
CONDITIONERS – AMPLIFIERS FOR STRAIN-GAUGE-BASED TRANSDUCERS
Actualizado: 2024-01-04
The COND-SGA conditioners - amplifiers provide standardised signals in current and voltage from every load cell, force transducer and torque sensor based on strain-gauge technology.o Input: Wheatstone bridge 0.1 to 30 mV/V
o Output: 4(0)...020 mA, -10...0...+10 V
o Power supply:
- COND-SGA-A: 1015...230 VAC / 018...24 VDC
- COND-SGA-D: 018...24 VDC
o Low-cost
o Enclosure: ABS case 0164 x 84 x 57 mm
MEASUREMENT TRANSMITTER FOR DC VOLTAGE AND CURRENT SIGNALS
Actualizado: 2024-01-04
Measurement transmitter designed to convert any not-normalised DC voltage or current signal into a normalised signal while providing galvanic insulation.o Voltage or current input
o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply
o Selection of input and output ranges by jumpers behind the front plate
o Wide range of power supplies
o Rail DIN mounting
o Weight: 130 g
o Compliant with EMC EN 500082-2
WEIGHING INDICATOR
Actualizado: 2024-01-04
Very-high-accuracy digital indicator designed for weighing applications.o Approved for 10.000 d OIML
o Up to 70 measurements per second
o Alibi-memory for 10.000 records
o Parallel connection of up to 10 strain-gauge load cells (350 ohms)
o Display resolution up to 99.000 d
o Bright, 6-digit, red LED display (014 mm)
o Serial RS-232 port for connection to serial printer, computer or remote display
o Desktop or industrial housing
o 1 digital input (programmable as tilt input or to tare scale remotely or others)
o 2 digital outputs (programmable as weight set-points or as other control outputs)
AVAILABLE OPTIONS- analogue output 4(0)...020 mA or 0.002...10 V
HAND-HELD DISPLAYS FOR STRAIN-GAUGE-BASED TRANSDUCERS
Actualizado: 2024-01-04
The INDI-PSD are hand-held indicators for load cells, force transducers or torque meters based on strain-gauge technology.o 7 digit LCD display
o High resolution
o Light (250 g)
o Dual range
o Large autonomy (450 h in power save mode)
o TEDS enabled
o RS-232 output (INDI-PSD232 only)
AVAILABLE OPTIONS- CASE-PSD: leather case with shoulder strap and clear viewing
- BATT-PSD: rechargeable batteries with charging unit (230 VAC)
RADIO TRANSMITTERS FOR ANALOGUE SIGNAL
Actualizado: 2024-01-04
The WI-T24TR-ACM is a wireless radio transmitter for analogue measurement signals. It is available in 3 housing versions and for 3 kinds of input signals (mV/V, V and mA).o Frequency: 2.4 GHz
o Power: 10 mW (licence: exemption)
o Range: 800 m (exception for WI-T24TR-ACMM: 500 m)
o High accuracy, high resolution
o Type:
- WI-T24TR-ACM:
- housing: 0164x84x57 mm, protection class IP67
- power supply: from 5 to 018 VDC or 2 x D cells (2 x 1.5 VDC)
- autonomy: with 2 alkaline 10 Ah cells: 280 days**
- WI-T24TR-ACMI:
- housing: 80x62x34 mm, protection class IP67
- power supply: 2 x AA cells (2 x 1.5 VDC)
- autonomy with 2 alkaline 2.2 Ah cells: 60 days**
- WI-T24TR-ACMM:
- housing: 76x35x020 mm, protection class IP50
- power supply: 2 x AAA cells (2 x 1.5 VDC)
see option WI-T24TR-ACMM-BATT on tehcnical drawings
- autonomy with 2 alkaline 1 Ah cells: 28 days**
o Antenna: integrated
HAND-HELD RADIO RECEIVERS WITH DISPLAY
Actualizado: 2024-01-04
The WI-T24RE-HS, WI-T24RE-HA and WI-T24RE-HR are hand-held indicators for sensors equipped with a radio transmitter.o Frequency: 2.4 GHz
o Licence: exemption
o Range: up to 800 m open field
o Antenna: integrated
o High resolution: 7 digits
o Channels:
- WI-T24RE-HS: 1
- WI-T24RE-HA: up to 012
- WI-T24RE-HR: displays all transmitters within its range (roaming)
AVAILABLE OPTIONS- leather carry case with clear viewing window and shoulder strap (CASE-PSD)
ANALOGUE INPUT LARGE PANEL METERS
Actualizado: 2024-01-04
Large panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso 5 digits of 38 mm height
o Intuitive and easy programming (high flexibility)
o 016 points scaling for linearisation
o Programmable function keys/user inputs
o Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...020 mA or 0...10 V
- 2 or 4 set-points with relay outputs
- RS-232, RS-485, fieldbus capabilities
- HOUSE-MAX: Housing
- HOUSE-MAX-IP: Housing with protection class IP64
ANALOGUE INPUT PANEL METERS WITH DUAL LINE DISPLAY
Actualizado: 2024-01-04
Panel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurementso Dual line display 6 digits (018 mm) and 9 digits (8.9 mm)o Tricolour display
o Universal power supply (AC/DC)
o Up to 0160 measurements per second
o Built-in USB programming port unit configurationAVAILABLE OPTIONS- Analogue output 4 (0)...020 mA or 0...10 V
- 2 or 4 set-points with relay outputs
- RS-232, RS-485 or fieldbus capabilities
- NEMA 4X / IP67 (transparent cover - Option \"COVER PAX\")
- Desktop or industrial steel housing
- DIN rail adaptor
DUAL INPUT DISPLAYS
Actualizado: 2024-01-04
Dual independent process input meters.o A math function can be performed on both signals.
o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card.
o Intuitive and easy programming (high flexibility)
o Variable intensity display
o 016 points scaling for linearisation
o Programmable function keys/user inputs
AVAILABLE OPTIONS- Analogue output 4 (0)...020 mA or 0...10 V
- 2 or 4 set-points with relay outputs
- RS-232, RS-485, USB or fieldbus capabilities
- NEMA 4X / IP67 (transparent protection cover - Option \"COVER PAX\")
- Desktop or industrial steel housing
- Rail DIN adaptor