000162 : Diaphragm/Piston Pressure Switch
Actualizado: 2024-01-04
Diaphragm & Piston Pressure SwitchesBlock Style (with O-ring NBR 5 x 1.5 mm)
Snap-Action Micro Switch with Silver Contacts
Field-Adjustable Pressure Range: 7.25…5,800 psi
Differential Set at Factory: 10..30%
Overpressure Safety: Up to 8,700 psi
Included DIN EN 01753001 (DIN 43650) connector
Aluminum body
Max.: 250 V
Seal material: NBR (Buna N), EPDM, FKM (Viton®)
Advantages:
Can be Field-Adjusted: Up to 5,800psi
Has a Factory-Settable Differential
Can be Manifold Mounted or by Direct Thread
The DIN Connector Makes Wiring Easy
000175 : Diaphragm/Piston Pressure Switch
Actualizado: 2024-01-04
Diaphragm pressure switch, socket device (low pressure) Performance:For low pressure, high accuracy
Field-Adjustable Pressure Range: 1.4 to 014 psi (0,1 to 1 bar)
Overpressure safety up to 363 psi (25 bar)
Temperature resistance: -30 °C … +100 °C
Socket device similar to DIN EN 01753001 (DIN 43650)
Aluminum body
Max.: 250 V
Seal material: NBR
000150 : Vacuum Switch
Actualizado: 2024-01-04
Vacuum Switches performance:Snap-Action Micro Switch with Silver Contacts
Field-adjustable pressure range: 3?…29?Hg
Differential: typically 1.5?..3?Hg
Overpressure Safety: Up to 290 psi (20 bar)
Included DIN EN 01753001 (DIN 43650) connector
Aluminum body
Max.: 250 V
Seal material: ECO
Advantages:
Can be easily wired with included DIN connector
Can be mounted two ways, either manifold or direct thread
Can handle Up to 290 psi Overpressure
000151 : Vacuum Switch
Actualizado: 2024-01-04
Vacuum Switches Performance:SPST-NO or SPST-NC
Field-adjustable pressure range: 6?…29?Hg
Overpressure Safety: Up to 290 psi
Spade or Screw Terminals
Brass body, HEX 24mm (0.95?)
Max: 42 V
Current: 4 A resistive
Seal material: FKM
Advantages:
Compact, small-sized vacuum switch for a wide range of industrial applications
Seal material is suitable for air, oils, greases, fuels
Can handle Up to 290 psi Overpressure
00410 : Diaphragm Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
00410 Deutsch DT004-2P Connector Performance:SPST-NO or SPST-NC
Overpressure safety: Up to 4,350 psi (300 bar)
Burst pressure safety: Up to 5,800 psi (400 bar)
Active reduction of EMC emissions
Deutsch DT004-2P Connector
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Overvoltage protection for prolonging the contact service life
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
RoHS Compliant
Advantages:
Has the advantages of a pressure switch but works like a Pressure Transducer with mA output. The value of mA output will change when the contact of the switch opens or closes. The value of the mA output is determined by the supply voltage and the resistors selected.
Up to 1,000 x Overpressure
No EMI issue
Recognizes line break
Recognizes short-circuit
No external excitation required
Field or factory adjustable
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
00411 : Piston Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
00411 Deutsch DT004-2P Connector Performance:Deutsch DT004-2P Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 725…2,0175 psi
Overpressure safety: Up to 8,700 psi (600 bar)
Burst pressure safety up to 10,0152 psi (700 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
A Varistor (MOV) integrated into the Pressure Switch Plus protects the contact rivets from the thermal stress of an inductive voltage which can cause premature wear and tear.
No additional parts required
Save costs (assembly, logistic)
Extended lifetime
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
004012 : Diaphragm Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
004012 AMP Superseal Pressure Switch Performance:AMP Superseal 1.5® Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 1.45…2,0175 psi
Overpressure safety: Up to 4,350 psi (300 bar)
Burst pressure safety: Up to 5,800 psi (400 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
Has the advantages of a pressure switch but works like a Pressure Transducer with mA output. The value of mA output will change when the contact of the switch opens or closes. The value of the mA output is determined by the supply voltage and the resistors selected.
Up to 1,000 x Overpressure
No EMI issue
Recognizes line break
Recognizes short-circuit
No external excitation required
Field or factory adjustable
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
00413 : Piston Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
00413 AMP Superseal 1.5 Connetor Performance:AMP Superseal 1.5® Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 725…2,0175 psi
Overpressure safety: Up to 8,700 psi (600 bar)
Burst pressure safety up to 10,0152 psi (700 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
A Varistor (MOV) integrated into the Pressure Switch Plus protects the contact rivets from the thermal stress of an inductive voltage which can cause premature wear and tear.
No additional parts required
Save costs (assembly, logistic)
Extended lifetime
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
004014 : Diaphragm Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
004014 Packard MetriPack 280 Performance:Packard MetriPack 280® Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 1.45…2,0175 psi
Overpressure safety: Up to 4,350 psi (300 bar)
Burst pressure safety: Up to 5,800 psi (400 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
Has the advantages of a pressure switch but works like a Pressure Transducer with mA output. The value of mA output will change when the contact of the switch opens or closes. The value of the mA output is determined by the supply voltage and the resistors selected.
Up to 1,000 x Overpressure
No EMI issue
Recognizes line break
Recognizes short-circuit
No external excitation required
Field or factory adjustable
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
004015 : Piston Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
Packard Metri-Pack 280 Connector Performance:Packard Metri-Pack 280® Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 725…2,0175 psi
Overpressure safety: Up to 8,700 psi (600 bar)
Burst pressure safety up to 10,0152 psi (700 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
A Varistor (MOV) integrated into the Pressure Switch Plus protects the contact rivets from the thermal stress of an inductive voltage which can cause premature wear and tear.
No additional parts required
Save costs (assembly, logistic)
Extended lifetime
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
004016 : Diaphragm Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
004016 Deutsch DT004-3P Connector Pressure Switch Performance:Deutsch DT004-3P Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 1.45…2,0175 psi
Overpressure safety: Up to 4,350 psi (300 bar)
Burst pressure safety: Up to 5,800 psi (400 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
Has the advantages of a pressure switch but works like a Pressure Transducer with mA output. The value of mA output will change when the contact of the switch opens or closes. The value of the mA output is determined by the supply voltage and the resistors selected.
Up to 1,000 x Overpressure
No EMI issue
Recognizes line break
Recognizes short-circuit
No external excitation required
Field or factory adjustable
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.
004017 : Piston Pressure Switch PLUS Fail-Safe
Actualizado: 2024-01-04
Deutsch DT004-3P Connector Performance:Deutsch DT004-3P Connector
SPST-NO or SPST-NC
Field-adustable pressure range: 725…2,0175 psi
Overpressure safety: Up to 8,700 psi (600 bar)
Burst pressure safety up to 10,0152 psi (700 bar)
Zinc-plated steel body, HEX 24mm (0.95?)
Max. working voltage: 8.2 VDC…30 VDC
Operating current: ? 30 mA
Withstands high-pressure wash and immersion (IP67)
Seal material: NBR (Buna N), EPDM, FKM (Viton®), HNBR
NAMUR Diagnostic function (fail-safe) with short-circuit and cable break detection
Advantages:
A Varistor (MOV) integrated into the Pressure Switch Plus protects the contact rivets from the thermal stress of an inductive voltage which can cause premature wear and tear.
No additional parts required
Save costs (assembly, logistic)
Extended lifetime
A wide-range of plug-in types, supplementary functions, seal materials, and accessories are available.