Conductivity Sensor HEAD

Código: CC21B

Código Interno: PRO13609

Actualizado: 2020-04-17

AquaSensor DataStick
Conductivity Sensor HEAD
• Range: 0.1 cell (0 to 500 uS/cm)
• Accuracy: 0.1% of reading
• Sensor Head Material: CPVC
• Temp/Press/Max Flow: -5C to 75C / 150 Psi/10 ft/sec
• Power: 10 to 30 Vdc
• Electrode Material: Titanium
• O-Ring: Viton

ORP SENSOR HEAD -2100mV to +2100 mV,

Código: ORP21A1A2

Código Interno: PRO13608

Actualizado: 2020-04-17

ORP SENSOR HEAD (ORP21A1A2)
• Range: -2100mV to +2100 mV
• Resolution: 0.1 mV
• Temp Operation / Max Pressure: -5C to 75 C/85Psi (CPVC Sensor)
• Max Flow Rate: 10 ft/sec
• Body Material / Electrode Type: CPVC / Platinium

AQUASENSOR DataStick Suspended Solids, 0-20,000 mg/L, MODBUS RTU, Cable Length: 30 Feet (9 mts)

Código: RT2143

Código Interno: PRO13579

Actualizado: 2020-04-17

RT2143
AQUASENSOR DataStick
* Suspended Solids
* 0-20,000 mg/L
* Resolution 1 mg/L
* Back Body and communication Material: CPCV
* Communication: MODBUS RTU
* Temp Range: -5 to 50 C
* Maximun Pressure: 150 Psi at 50°C
* Maximun Flow Rate: 10ft/sec

Conductivity Sensor HEAD ,0.1 cell (0 to 500 uS/cm), 10 to 30 Vdc

Código: CC31B

Código Interno: PRO13556

Actualizado: 2020-04-17

AquaSensor DataStick
Conductivity Sensor HEAD
• Range: 0.1 cell (0 to 500 uS/cm)
• Accuracy: 0.1% of reading
• Sensor Head Material: PEEK
• Temp/Press/Max Flow: -5C to 95C / 150 Psi/10 ft/sec
• Power: 10 to 30 Vdc
• Electrode Material: Titanium
• O-Ring: Viton

Wash Head Assembly

Código: MH1222

Código Interno: PRO13202

Actualizado: 2020-04-17

MH1222
Wash Head Assembly

52002559-C-H

Código: 52002559-C-H

Código Interno: PRO11757

Actualizado: 2020-12-21

MODEL: 52002559-C-H
PH SENSOR (52002559-C-H)
PH, general purpose & Moderate Pure Water
Rating: 0-100 C / 60 Psi
Temperature compensator: PT1000
PH Range: 0-14
Maximum Flow: 10ft/s (3 m/s)
INCLUDE:
=========’
Cable 5 mts Length
Housing SS

Digital Conductivity Sensor K=5 HACH

Código: D3422D3

Código Interno: PRO3961

Actualizado: 2020-04-23

Digital Contacting Conductivity Sensor for High Conductivity (k=5.0)
* Cell constant (K)=5
* 3/4 inch NPT Kynar (PVDF) compression fitting style
* Cable Lenght: Standard Probe Cable Length (integral)Digital Probe: 7 m (23 ft.)
​HACH

CONDUCTIVITY ELECTRODO, 3/4″ NPT, 0.02-2,000 uS/cm

Código: 58031220

Código Interno: PRO3486

Actualizado: 2020-12-21

MODEL: 58031220
CONDUCTIVITY ELECTRODO
Brand: THORNTON
Range: 0.02-2,000 uS/cm
Fitting: 3/4\" NPT
Cable Lenght: 30 ft (9 Mts)
Connector: Tinned Leads/NO Patch Cord required
Insertion Length of probe: 34mm
M300 Analytical Sensor

Electrode Kit for Orion Sodium Analyzer 2111XP

Código: 2111XPEK

Código Interno: PRO45404

Actualizado: 2021-08-23

Electrode Kit for Orion Sodium Analyzer 2111XP
Includes:
• Sodium electrode
• Reference electrode and
• (1) x 2 oz bottle reference electrode filling solution

​WATERPROOF PORTABLE METER KIT, (pH)16

Código: PH-150

Código Interno: PRO44928

Actualizado: 2021-07-21

​WATERPROOF PORTABLE METER KIT, (pH)16
Brand: OAKTON
Meter Type Portable
Display type3 line custom LCD
Connections BNC
Min pH (pH)-2
Max pH (pH)16
pH Resolution0.01
pH Accuracy±0.01
Buffer RecognitionDIN, NIST, and USA

Medidor de turbidez para laboratorio

Código: RS232-USB

Código Interno: PRO44569

Actualizado: 2021-07-21

Cable de datos RS232-USB
Producto: Cable
Características
Cable de datos RS232-USB para conectar PC 1,5 m (5 pies)

Medidor de turbidez para laboratorio

Código: Software-DT9011

Código Interno: PRO44566

Actualizado: 2021-07-21

DT9011 PC-Transfer-B3
Producto: Software
Características
Este software para PC permite a los usuarios:
Descargar conjuntos de datos del registrador de datos desde DT9011 -> PC
Descargar juegos de parámetros de DT9011 -> PC
Cargar conjuntos de parámetros guardados o clonados desde PC -> DT9011
Cargue el firmware del convertidor estándar desde la PC -> DT9011
Memoria USB incluye: C64
- Software DT9011 PC-Transfer
- Firmware estándar DT9011 en versión C real
Manual en alemán, inglés, español, ruso y chino
Nota: El cable de datos RS232-USB debe pedirse por separado