Mostrando 37–48 de 3008 resultados

g2x10xq9gma computer display metal body g2 ss aluminum

Código: G2X10XQ9GMA Q9 Computer Display for G2 1" Metal Body (Replacement for Q9 computer display only)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits G2 metal bodies with no plastic backplate on back, sizes 1\" NPTF, 1\" Flanged or 1-1/2\" Tri-Clamp connections only. The model number on the back side must have Q9 in it as it replaces the Q9 computer display.LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. G2X10XR9GMA

0 F to 140 F (-18 C to 60 C)

g2x10xr9gma computer display metal body g2 ss aluminum

Código: G2X10XR9GMA R9 Computer Display for G2 1" Metal Body (Retrofits 09 or Q9 computer display)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, sensor, batteries, o\'ring seal, gasket, screws, manual and declaration of conformityFits G2 metal bodies with 1\" NPTF, 1\" Flanged or 1-1/2\" Tri-Clamp connections only. This computer display replaces either the older 09 or Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.

0 F to 140 F (-18 C to 60 C)

g2x15xq9gma computer display metal body g2 ss aluminum

Código: G2X15XQ9GMA Q9 Computer Display for G2 1-1/2" Metal Body (Replacement for Q9 computer display only)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits G2 metal bodies with no plastic backplate on back, sizes 1-1/2\" NPTF, 1-1/2\" Flanged or 2\" Tri-Clamp connections only. The model number on the back side must have Q9 in it as it replaces the Q9 computer display.LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. G2X15XR9GMA

0 F to 140 F (-18 C to 60 C)

g2x15xr9gma computer display g2 ss aluminum body

Código: G2X15XR9GMA R9 Computer Display for G2 1-1/2" Metal Body (Retrofits 09 or Q9 computer display)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, sensor, batteries, o\'ring seal, gasket, screws, manual and declaration of conformityFits G2 metal bodies with 1-1/2\" NPTF, 1-1/2\" Flanged or 2\" Tri-Clamp connections only. This computer display replaces either the older 09 or Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.

0 F to 140 F (-18 C to 60 C)

g2x20xq9gma computer display metal body g2 ss aluminum

Código: G2X20XQ9GMA Q9 Computer Display for G2 2" Metal Body (Replacement for Q9 computer display only)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits G2 metal bodies with no plastic backplate on back, sizes 2\" NPTF, 2\" Flanged or 2-1/2\" Tri-Clamp connections only. The model number on the back side must have Q9 in it as it replaces the Q9 computer display.LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. G2X20XR9GMA

0 F to 140 F (-18 C to 60 C)

g2x20xr9gma computer display g2 ss aluminum body

Código: G2X20XR9GMA R9 Computer Display for G2 2" Metal Body (Retrofits 09 or Q9 computer display)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, sensor, batteries, o\'ring seal, gasket, screws, manual and declaration of conformityFits G2 metal bodies with 2\" NPTF, 2\" Flanged or 2-1/2\" Tri-Clamp connections only. This computer display replaces either the older 09 or Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.

0 F to 140 F (-18 C to 60 C)

g2z05x09gma computer display g2 pvdf body meters

Código: G2Z05X09GMA 09 Computer Display for G2 1/2" PVDF Body (Very Limited Stock)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformityFits G2 PVDF 1/2\" meter onlyLCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 3V Lithium batteries; Battery life (5 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.

0 F to 140 F (-18 C to 60 C)

g2z05xq9gma computer display g2 pvdf body

Código: G2Z05XQ9GMA Q9 Computer Display for G2 1/2" PVDF Body (Replacement for Q9 computer display only)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits G2 PVDF bodies with 1\" NPTF connection only. The model number on the side must contain Q9 as this computer display replaces only the Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. G2Z05XR9GMA

0 F to 140 F (-18 C to 60 C)

g2z05xr9gma computer display g2 pvdf body

Código: G2Z05XR9GMA R9 Computer Display for G2 1/2" PVDF Body (Retrofits 09 or Q9 computer display)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, sensor, batteries, o\'ring seal, gasket, screws, manual and declaration of conformityFits G2 PVDF bodies with 1/2\" NPTF connection only. This computer display replaces either the older 09 or Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.

0 F to 140 F (-18 C to 60 C)

g2z10x09gma computer display g2 pvdf body meters

Código: G2Z10X09GMA 09 Computer Display for G2 1" PVDF Body (Very Limited Stock)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformityFits G2 PVDF 1\" meter onlyLCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 3V Lithium batteries; Battery life (5 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.

0 F to 140 F (-18 C to 60 C)

g2z10xq9gma computer display g2 pvdf body

Código: G2Z10XQ9GMA Q9 Computer Display for G2 1" PVDF Body (Replacement for Q9 computer display only)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits G2 PVDF bodies with 1/2\" NPTF connection only. The model number on the side must contain Q9 as this computer display replaces only the Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. G2Z10XR9GMA

0 F to 140 F (-18 C to 60 C)

g2z10xr9gma computer display g2 pvdf body

Código: G2Z10XR9GMA R9 Computer Display for G2 1" PVDF Body (Retrofits 09 or Q9 computer display)
Valorado con 0 de 5

Actualizado: 2024-03-07

Features & Benefits
Kit consists of Computer Display, sensor, batteries, o\'ring seal, gasket, screws, manual and declaration of conformityFits G2 PVDF bodies with 1\" NPTF connection only. This computer display replaces either the older 09 or Q9 computer display. LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Alkaline batteries. Battery life (2 years); Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative); Factory Calibration in gallons and liters; User Calibration and Rate of Flow Indication; Totalizing Registers: 0 to 2; K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit; Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry; Readouts: LCD with floating decimal Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits); Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz; Storage Temperature: -40 F to 158 F (-40 C to 70 C); Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.

0 F to 140 F (-18 C to 60 C)