a1q9gmx025xb3 computer display a1 low flow aluminum nylon body
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits A1 Aluminum or Nylon bodies only. Replaces LCD computer display labeled A1Q9GMA025NA1, A1Q9GMN025NA1, A1Q9LMA025NA1, A1Q9LMN025NA1 or A1Q9GMX025XB3LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. A1R9GMX025XB3
0 F to 140 F (-18 C to 60 C)
a1q9gmx100xb3 computer display a1 aluminum nylon body
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits A1 Aluminum or Nylon bodies only. Replaces LCD computer display labeled A1Q9GMA100NA1, A1Q9GMN100NA1, A1Q9LMA100NA1, A1Q9LMN100NA1 or A1Q9GMX100XB3.LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. A1R9GMX100XB3
0 F to 140 F (-18 C to 60 C)
a1q9gmx200xb3 computer display a1 aluminum body
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, batteries, O\'ring seal, gasket, screws, manual and declaration of conformity (does not contain sensor)Fits A1 Aluminum 2\" body only. Replaces LCD computer display labeled A1Q9GMA200NA2, A1Q9LMA200NA2 or A1Q9GMX200XB3.LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE Q9 COMPUTER DISPLAY, PURCHASE PART NO. A1R9GMX200XB3
0 F to 140 F (-18 C to 60 C)
a1r9gmx025xb3 computer display a1 low flow aluminum nylon
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, sensor, batteries, O\'ring seal, gasket, screws, manual and declaration of conformityFits A1 Aluminum or Nylon bodies only. Replaces LCD computer display labeled A109GMA025NA1, A109GMN025NA1, A109LMA025NA1, A109LMN025NA1, A109GMX025XB3 or A1Q9GMA025NA1, A1Q9GMN025NA1, A1Q9LMA025NA1, A1Q9LMN025NA1, A1Q9GMX025XB3 or A1Q9GMA025NA1, A1R9GMN025NA1, A1R9LMA025NA1, A1R9LMN025NA1, A1R9GMX025XB3LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.
0 F to 140 F (-18 C to 60 C)
a1r9gmx100xb3 replacement computer display a1 aluminum nylon body
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, sensor, batteries, O\'ring seal, gasket, screws, manual and declaration of conformityFits A1 Aluminum or Nylon bodies only. Replaces LCD computer display labeled A109GMA100NA1, A109GMN100NA1, A109LMA100NA1, A109LMN100NA1, A109GMX100XB3 or A1Q9GMA100NA1, A1Q9GMN100NA1, A1Q9LMA100NA1, A1Q9LMN100NA1, A1Q9GMX100XB3 or A1R9GMA100NA1, A1R9GMN100NA1, A1R9LMA100NA1, A1R9LMN100NA1, A1R9GMX100XB3LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.
0 F to 140 F (-18 C to 60 C)
a1r9gmx200xb3 retrofit computer display a1 aluminum nylon
Actualizado: 2024-03-07
Features & BenefitsKit consists of Computer Display, sensor, batteries, O\'ring seal, gasket, screws, manual and declaration of conformityFits A1 Aluminum 2\" body only. Replaces LCD computer display labeled A109GMA200NA2, A109LMA200NA2, A109GMX200XB3 or A1Q9GMA200NA2, A1Q9LMA200NA2, A1Q9GMX200XB3 or A1R9GMA200NA2, A1R9LMA200NA2, A1R9GMX200XB3LCD Computer Display programmed to display in Gallons Per Minute. Flowrate display updates every 5 seconds, readout is in units/minute. Factory Calibration in gallons and liters is standard. Can be field calibrated to adjust to various fluid viscosities. Correction calibration lets end user calibrate by ± percent off.Internal Power: (2) 1.5V Akaline batteries. Battery life (2 years). Std Factory Configuration: 2 Totals (1 Resettable, 1 Cumulative). Factory Calibration in gallons and liters. Totalizing Registers: 0 to 2, K-Factor Limits: Min: .01 pulses/unit Max: 999,999 pulses/unit. Field Calibrate by user. Standard Method: Correction Factor. Six adjustable digits. Can be reconfigured to K-factor entry. Readouts: LCD with floating decimal. Minimum Display = 0.01 units Maximum Display = 999,999 units (6 digits). Impulse Rate: Minimum (Pulse-in Input) = DC (0 Hz) Minimum (Coil Input) = Approximately 10 Hz Maximum = Approximately 1,000 Hz. Storage Temperature: -40 F to 158 F (-40 C to 70 C). Note: Part number is dependent on material and size of flow meter.IF NOT CERTAIN THAT YOU ARE REPLACING THE COMPUTER DISPLAY 09, Q9 OR R9 - PURCHASE THIS PART NO.
0 F to 140 F (-18 C to 60 C)