Mostrando 1–36 de 90 resultados

TENSION AND COMPRESSION LOAD CELLS

Código: 2710-2715
Valorado con 0 de 5

Código Interno:

Reference : 2710-2715Universal load cells combining accuracy, sturdiness and easy installationo Material: - 2710: stainless steel - 2715: alloy steelo Protection class: IP67o Compact designo Cable length: see drawing table - CL (other lengths available on request)Technical drawings available on datasheet

HIGH-CAPACITY NON-CONTACT ROTARY TORQUE SENSORS

Código: 65000
Valorado con 0 de 5

Código Interno:

Reference : 65000General purpose, high capacity non-contact rotary torque sensors.o Bidirectionalo Measurement range up to 25 kN·m (>25 kN·m on request)o Rotating speed up to 8000 rpmo Integrated signal conditioningo Analogue output signal (see Wiring table)o Cable length: 5 mTechnical drawings available on datasheet

ANALOGUE INPUT LARGE PANEL METERS

Código: INDI-MAXS DISP-MAX
Valorado con 0 de 5

Código Interno:

Reference : INDI-MAXS DISP-MAXLarge panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso 5 digits of 38 mm heighto Intuitive and easy programming (high flexibility)o 16 points scaling for linearisationo Programmable function keys/user inputso Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485, fieldbus capabilities- HOUSE-MAX- HOUSE-MAX-IP: protection class IP64

FUNCTIONAL SAFETY CERTIFIED LOAD LIMITER ELECTRONICS

Código: SAFETY-BOY
Valorado con 0 de 5

Código Interno:

Reference : SAFETY-BOYOverload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1.o 2 redundant channels with constant comparing of both signalso PFHd 4.29 x 10E-08o Load limiter electronics certified for functional safety up to PL d Category 3, DC: mediumo Display of hoisted load and input signalo Monitoring system of the integrity of load cells with continuous comparison of both channels and internal \"watchdog\" for the electronicso Analogue output: 2 x 4...20 mA\"Technical drawings available on datasheet\"

HAND-HELD RADIO RECEIVERS WITH DISPLAY

Código: WI-T24RE-Hx
Valorado con 0 de 5

Código Interno:

Reference : WI-T24RE-HxThe WI-T24RE-HS, WI-T24RE-HA and WI-T24RE-HR are hand-held indicators for sensors equipped with a radio transmitter.o Frequency: 2.4 GHzo Licence: exemptiono Range: up to 800 m open fieldo Antenna: integratedo High resolution: 7 digits o Channels: - WI-T24RE-HS: 1 - WI-T24RE-HA: up to 12 - WI-T24RE-HR: displays all transmitters within its range (roaming)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- leather carry case with clear viewing window and shoulder strap (CASE-PSD)

CONTAINER WEIGHING SYSTEM

Código: SPREADER-BOY
Valorado con 0 de 5

Código Interno:

Reference : SPREADER-BOYNew generation of electronic data logging for weighing containers during handling. This one is designed to meet the new SOLAS requirement making it mandatory for containers to be weighed before they are loaded on board ships.o 4 or 8 x 4-20 mA analogue inputs for force transducerso 4 digital inputs (start, stop and tare signal)o 2 output relay able to signal an alarm (audible, luminous warning signal, etc.)o Analogue outputs according to the measurementso Data recording on a CompactFlash memory cardo Colour touch screeno Ethernet connectiono RS-485 / PROFIBUAS interface (option)\"Technical drawings available on datasheet\"

ANALOGUE INPUT PANEL METERS

Código: INDI-PAXS DISP-PAX
Valorado con 0 de 5

Código Interno:

Reference : INDI-PAXS DISP-PAXUniversal panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso Intuitive and easy programming (high flexibility)o 16 points scaling for linearisationo Programmable function keys/user inputso Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485, USB or fieldbus capabilities- NEMA 4X / IP65 (transparent protection cover - Option \"COVER PAX\")- Desktop or industrial steel housing- Rail DIN adaptor

ANALOGUE INPUT PANEL METERS WITH DUAL LINE DISPLAY

Código: INDI-PAX2S DISP-PAX2A
Valorado con 0 de 5

Código Interno:

Reference : INDI-PAX2S DISP-PAX2APanel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurementso Dual line display 6 digits (18 mm) and 9 digits (8.9 mm)o Tricolour displayo Universal power supply (AC/DC)o Up to 160 measurements per secondo Built-in USB programming port unit configurationAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485 or fieldbus capabilities- NEXMA 4X / P65 (transparent cover - Option \"COVER PAX\")- Desktop or industrial steel housing- DIN rail adaptor

CRANE OVERLOAD PROTECTION ELECTRONICS

Código: INDI-BOY DISP-BOYP
Valorado con 0 de 5

Código Interno:

Reference : INDI-BOY DISP-BOYPCrane overload protection electronics with 3 set-points and display to be installed on a front panel.o Easy and intuitive calibrationo Display of hoisted load and input signalo Internal monitoring system of load cell integrity and load limitation electronics (fail safe)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- RS-232, RS-485 or fieldbus capabilities- NEMA 4X / IP65 (transparent protection cover + Option \"COVER PAX\")- rail DIN adaptor- power supply: 48 VAC (only for 85...230 VAC version)- also available with industrial metallic housing (see CRANE-BOY and CRANE-BOYP products)

DISPLAY FOR RUNNING LINE TENSIOMETERS

Código: DISP-RLT
Valorado con 0 de 5

Código Interno:

Reference : DISP-RLT3-channel display specially designed to work in combination with SENSY running line tensiometers 5570, 5575, 5580 and 5585 for winches and running cables in order to display the tensile load, the speed and the pay-out.o Inputs: - force transducer - payout sensoro Digital displays and bar graphs: - force - speed - payouto Data transmission\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- data logging (download by USB stick or Ethernet network)- communication output RS-232, RS-485- analogue output 4 (0)...20 mA or 0...10 V- relay output 2 or 4 FORM-C (5 A, 230 VAC resistive load)- power supply: 110 & 230 VAC (50 - 60 Hz)

CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES

Código: DISP-BOYDP-CRANE
Valorado con 0 de 5

Código Interno:

Reference : DISP-BOYDP CRANE-BOYDPElectronics ensuring the individual limitation of loads lifted by 2 hoisting systems and limitation of the function of these loads (sum, difference, multiplication, ratio)o Type: - DISP-BOYDP: to be installed on the front panel - CRANE-BOYDP: with industrial metallic housing o Easy and intuitive calibrationo Display of hoisted loads and input signalso Internal monitoring system of the integrity of load cells and load limitation electronics (fail safe)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- RS-232, RS-485 or fieldbus capabilities- NEMA 4X/IP65 (transparent protection cover + Option \"COVER PAX\")- rail DIN adaptor- power supply: 48 VAC (only for 85...230 VAC version)- stainless steel housing

STRAIN-GAUGE EMBEDDED DIGITAL CONVERTERS

Código: DIGITAL CONVERTERS
Valorado con 0 de 5

Código Interno:

Reference :These digital converters convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USBo Very high resolutiono Linearisation of transducer signal availableo High transmission speedo Internal or external mounting depending on the size of the transducero When external, rectangular box in aluminium (protection class IP65)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- temperature measurement with compensation of thermal drifts

CRANE OVERLOAD PROTECTION ELECTRONICS FOR THE SUM OF SEVERAL CHANNELS

Código: CRANE-SUMD DISP-
Valorado con 0 de 5

Código Interno:

Reference : CRANE-SUMD DISP-SUMDCRANE-SUMD and DISP-SUMD are designed to limit the sum of the load of several hoisting devices already equipped with their own load limitation device.o Type: - CRANE-SUMD: with industrial metallic housing - DISP-SUMD: to be installed on the front panel o Connected to the analogue output (4...20 mA) of the load limitation electronics BRIDGE-BOY, CRANE-BOY, INDI-BOY, DISP-BOYP, etc. (CARD-CDL10 option)o Easy and intuitive calibrationo Display of hoisted load and input signals\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- analogue output 4(0)...20 mA / 0...10 V- RS-232, RS-485 or fieldbus output- stainless steel housing- NEMA 4X/IP65 (transparent protection cover - Option \"COVER PAX\")- rail DIN adaptor

CRANE OVERLOAD PROTECTION ELECTRONICS (EXPLOSION-PROOF)

Código: CRANE-BOY Exd
Valorado con 0 de 5

Código Interno:

Reference : CRANE-BOY-Exd CRANE-BOYP-ExdCRANE-BOY-Exd and CRANE-BOYP-Exd are CRANE-BOY mounted in an explosion-proof housing to be used in an hazardous area. They are equipped and standardised with Zener barriers in order to be connected to an Ex i certified fload cell.o Certified for IIB group (also available for IIC group)o Easy and intuitive calibrationo Display of hoisted load and input signalo Internal monitoring system of load cell integrity and load limitation electronics (fail safe)o Also available without Zener barrier for using with Ex d certified load pins: CRANE-BOY-Exd-5050\"Technical drawings available on datasheet\"

CRANE OVERLOAD PROTECTION ELECTRONICS

Código: CRANE-BOY CRANE
Valorado con 0 de 5

Código Interno:

Reference : CRANE-BOY CRANE-BOYPCrane overload protection electronics with 3 set-points and displayo Easy and intuitive calibrationo Display of hoisted load and input signalo Internal monitoring system of load cell integrity and load limitation electronics (fail safe)o Test button on front covero Also available without industrial metallic housing (see INDI-BOY, DISP-BOYP and DISP-SUMD)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- RS-232, RS-485 or fieldbus capabilities- NEMA 4X / IP65 (transparent protection cover + Option \"COVER PAX\")- Power supply: 48 VAC (only for 85...230 VAC version)- Stainless steel housing

DATA RECORDING AND MANAGEMENT FOR EOT CRANES

Código: COACH-II
Valorado con 0 de 5

Código Interno:

Reference : COACH-IIThe COACH-II is a data recording system specially dedicated to crane monitoring. o The COACH-II is a new generation of electronic data logging, monitoring and management system for overhead travelling cranes (EOT), adaptable to other types of crane.o It is designed to optimise the maintenance with full knowledge of mechanical stress during use.o It can be used as a \"black box\" tracing the history of all recent movements.\"Technical drawings available on datasheet\"

STRAIN-GAUGE EMBEDDED ANALOGUE AMPLIFIERS

Código: ANALOGUE AMPLIFIERS
Valorado con 0 de 5

Código Interno:

Reference :These analogue amplifiers convert the signal from a Wheatstone bridge (mV/V) into a robust industrial standardised analogue signal.o Internal or external mounting depending on the size of the transducero If external, cylindrical housing in nickel-plated brass (IP67) or rectangular box in aluminium (low-cost version) (IP65)o Available version with shifted zero for bidirectional utilisation for versions 4...20 mA and 0...10 V.o Protection against inversion of polarityo Cable length: 0.15 m between the amplifier housing and the transducer (max. 0.5 m)\"Technical drawings available on datasheet\"\"Technical drawings available on datasheet\"

RADIO TRANSMITTERS FOR ANALOGUE SIGNAL

Código: WI-T24TR-ACM
Valorado con 0 de 5

Código Interno:

Reference : WI-T24TR-ACMThe WI-T24TR-ACM is a wireless radio transmitter for analogue measurement signals. It is available in 3 housing versions and for 3 kinds of input signals (mV/V, V and mA).o Frequency: 2.4 GHzo Power: 10 mW (licence: exemption)o High accuracy, high resolutiono Type: - WI-T24TR-ACM: - housing: 164x84x57 mm, protection class IP67 - range: 800 m - power supply: from 5 to 18 VDC or 2 x D cells (2 x 1.5 VDC) - autonomy: with 2 alkaline 10 Ah cells: 280 days** - WI-T24TR-ACMI: - housing: 80x62x34 mm, protection class IP67 - range: 800 m - power supply: 2 x AA cells (2 x 1.5 VDC) - autonomy with 2 alkaline 2.2 Ah cells: 60 days** - WI-T24TR-ACMM: - housing: 76x35x20 mm, protection class IP50 - range: 500 m - power supply: 2 x AAA cells (2 x 1.5 VDC) - autonomy with 2 alkaline 1 Ah cells: 28 days**o Antenna: integrated\"Technical drawings available on datasheet\"

MULTICHANNEL WIRELESS RECEIVER WITH DIGITAL OUTPUT

Código: WI-T24RE-SO
Valorado con 0 de 5

Código Interno:

Reference : WI-T24RE-SOThe WI-T24RE-SO is a base station designed to connect up to 8 transducers provided by a wireless transmitter WI-T24TR-ACM-xA to a PC or a PLC. It achieves configuration, calibration and data acquisition of each one or all of them.o Frequency: 2.4 GHzo Power: 10 mWo License: exemptiono Range: up to 800 m open fieldo Antenna: integrated\"Technical drawings available on datasheet\"

WIRELESS RECEIVERS WITH DIGITAL OUTPUTS

Código: WI-T24RE-BSx
Valorado con 0 de 5

Código Interno:

Reference : WI-T24RE-BSxWI-T24RE-BSU, -BSUE and -BSI are base stations designed to connect every transducer provided by a wireless transmitter (WI-T24TR-ACM-xA) to a PC or a PLC in order to achieve its configuration, calibration and data acquisition.o Frequency: 2.4 GHzo Power: 10 mWo Licence: exemptiono Range: up to 800 m open fieldo Antenna: integrated\"Technical drawings available on datasheet\"

WIRELESS ANALOGUE OUTPUT RECEIVER MODULES

Código: WI-T24RE-AO1
Valorado con 0 de 5

Código Interno:

Reference : WI-T24RE-AO1WI-T24RE-AO1 and WI-T24RE-AO1I convert data from a WI-T24TR-ACM module into an analogue output.o Voltage and current outputo Frequency: 2.4 GHzo Licence: exemptiono Up to 2000 updates / so High accuracyo High resolutiono Industrial (WI-T24RE-AO1I) and desktop (WI-T24RE-AO1) versions available\"Technical drawings available on datasheet\"

SMART JUNCTION BOX MONITORING LOAD CELL INTEGRITY

Código: JBOX-LCI
Valorado con 0 de 5

Código Interno:

Reference : JBOX-LCISmart junction box is designed for parallel connecting of 2 to 4 load cells to an electronic device and for ensuring the monitoring of their correct functioning.o Control of: - load cell out of pre-set balance range - load cell out of pre-set operating range - low / high excitation - open circuit to any load cell on each connection - short circuit on any load cell connection - internal load cell fault (bridge imbalance)o Ensure the positive safety of load limitation systems based on multiple load cells connected in parallel (hoisting devices)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- ABS housing available with DIN rail mounting accessories- PCB available without ABS housing

JUNCTION BOXES FOR WEIGHING SYSTEMS

Código: JBOX
Valorado con 0 de 5

Código Interno:

Reference : JBOXJunction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment.o 4 or 6 inputso Connection in 4 or 6 wireso Cabling of load cells and electronics by screw terminals o Waterproof\"Technical drawings available on datasheet\"

HAND-HELD DISPLAYS FOR STRAIN-GAUGE-BASED TRANSDUCERS

Código: INDI-PSD
Valorado con 0 de 5

Código Interno:

Reference : INDI-PSDThe INDI-PSD are hand-held indicators for load cells, force transducers or torque meters based on strain-gauge technology.o 7 digit LCD displayo High resolutiono Light (250 g)o Dual rangeo Large autonomy (450 h in power save mode)o TEDS enabledo RS-232 output (INDI-PSD232 only)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- CASE-PSD: leather case with shoulder strap and clear viewing - BATT-PSD: rechargeable batteries with charging unit (230 VAC)

INDICATOR FOR STANDARD REFERENCE FORCE TRANSDUCERS

Código: INDI-ISO376
Valorado con 0 de 5

Código Interno:

Reference : INDI-ISO376The INDI-ISO376 is a very high-accuracy portable indicator designed to be used in combination with standard reference force transducers with accuracy classes 1, 0,5 or 00 according to ISO 376 standard.o High accuracy: 0.01% o High resolution o 6-wire connection\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- acquisition and management software

WEIGHING INDICATOR

Código: INDI-5250
Valorado con 0 de 5

Código Interno:

eference : INDI-5250Very-high-accuracy digital indicator designed for weighing applications.o Approved for 10.000 d OIML o Up to 70 measurements per second o Alibi-memory for 10.000 records o Parallel connection of up to 10 strain-gauge load cells (350 ohms) o Display resolution up to 99.000 d o Bright, 6-digit, red LED display (14 mm) o Serial RS-232 port for connection to serial printer, computer or remote displayo Desktop or industrial housingo 1 digital input (programmable as tilt input or to tare scale remotely or others) o 2 digital outputs (programmable as weight set-points or as other control outputs)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- analogue output 4(0)...20 mA or 0.02...10 V

LOAD CELL INDICATOR FOR TESTING MACHINE CONTROL

Código: INDI-12390
Valorado con 0 de 5

Código Interno:

Reference : INDI-12390Standard reference indicator specially designed to display the 4 signals generated by the 3115F-12390 load cell. It is designed for the control of concrete testing machines according to EN12390-4 and DIN 51302-2 standards.- Compliant with EN 12390-4 and DIN 51302-2 standards- 4 independent displays- Resolution: 5 digits- Robust industrial housing- Digital output: RS-485\"Technical drawings available on datasheet\"AVAILABLE OPTIONSo analogue output: 0...10 V or 4...20 mA

DISPLAY FOR STANDARD REFERENCE FORCE TRANSDUCERS

Código: INDI-00
Valorado con 0 de 5

Código Interno:

Reference : INDI-00The INDI-00 is a high-accuracy portable indicator designed to be used in combination with standard reference force transducers with accuracy classes 1, 0,5 and 00*** according to ISO 376 standard.o High accuracy: 0.01%o High resolution: 5 1/2 digitso 6-wire connectiono RS-232 output\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- acquisition and management software- working with rechargeable battery (charger included)

DUAL INPUT DISPLAYS

Código: DISP-PAXDP
Valorado con 0 de 5

Código Interno:

Reference : DISP-PAXDPDual independent process input meters.o A math function can be performed on both signals. o Any of the 3 meter values can have alarms, analogue output or comms by adding optional card.o Intuitive and easy programming (high flexibility)o Variable intensity displayo 16 points scaling for linearisationo Programmable function keys/user inputs\"Technical drawings available on datasheet\"

LARGE DIGITAL DISPLAYS

Código: DISP-F
Valorado con 0 de 5

Código Interno:

Reference : DISP-FLarge digital displays for distance reading.DISP-Fx-yz x = input - P: process input: 0...10 V and 4(0)...20 mA - S2: RS-232 - S4: RS-485 y = Digits (4 or 6) z = Digits height: - DISP-Fx-y2: 57 mm - DISP-Fx-y4: 102 mm - DISP-Fx-y6: 150 mm - DISP-Fx-y8: 200 mm - DISP-Fx-y12: 300 mm - DISP-Fx-y16: 400 mm - other on request\"Technical drawings available on datasheet\"

MEASUREMENT TRANSMITTER FOR DC VOLTAGE AND CURRENT SIGNALS

Código: CONV-UI
Valorado con 0 de 5

Código Interno:

Reference : CONV-UIMeasurement transmitter designed to convert any not-normalised DC voltage or current signal into a normalised signal while providing galvanic insulation.o Voltage or current inputo Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supplyo Selection of input and output ranges by jumpers behind the front plateo Wide range of power supplieso Rail DIN mountingo Weight: 130 go Compliant with EMC EN 50082-2\"Technical drawings available on datasheet\"

STRAIN-GAUGE BRIDGE TO USB CONVERTER

Código: COND-USB
Valorado con 0 de 5

Código Interno:

Reference : COND-USBThe COND-USB converts the signal from a Wheatstone bridge (mV/V) into a USB signal.o High accuracyo Very high resolutiono Linearisation of transducer signal availableo Toolkit software includedo ABS IP50 enclosureo DB9 socket @ load cell sideo Micro USB socket with 1.5 m cable\"Technical drawings available on datasheet\"

CONDITIONERS – AMPLIFIERS FOR STRAIN-GAUGE-BASED TRANSDUCERS

Código: COND-SGA
Valorado con 0 de 5

Código Interno:

Reference : COND-SGAThe COND-SGA conditioners - amplifiers provide standardised signals in current and voltage from every load cell, force transducer and torque sensor based on strain-gauge technology.o Input: Wheatstone bridge 0.1 to 30 mV/Vo Output: 4(0)...20 mA, -10...0...+10 Vo Power supply: - COND-SGA-A: 115...230 VAC / 18...24 VDC - COND-SGA-D: 18...24 VDC o Low-costo Enclosure: ABS case 164 x 84 x 57 mm\"Technical drawings available on datasheet\"

CONDITIONERS – AMPLIFIERS FOR STRAIN-GAUGE-BASED TRANSDUCERS

Código: COND-A420
Valorado con 0 de 5

Código Interno:

Reference : COND-A420The COND-A420 conditioners - amplifiers provide standardised signals in current and voltage from every load cell, force transducer and torque sensor based on strain-gauge technology.o Input range: Wheatstone bridge (4 or 6 wires connection (sense))o Output: 4(0)...20 mA and 0...10 V (simultaneously)o Sensor excitation: 10 V (120 mA max.) available for up to 4 x 350 ohms. Load cells connected in parallelo DIN rail mounting\"Technical drawings available on datasheet\"

CRANE OVERLOAD PROTECTION ELECTRONICS FOR 4 CHANNELS + SUM

Código: CABIN-4xB1SUMD
Valorado con 0 de 5

Código Interno:

Reference : CABIN-4xB1SUMDThe CABIN-4IB1SUMD and CABIN-4DB1SUMD are crane overload protection systems designed to manage 4 hoisting devices as well as the sum of the loads. x = input: - I: mV/V or - D: process input 4(0)...20 mAo Easy and intuitive calibrationo Display of hoisted loads and input signalso Internal monitoring system of load cell integrity and load limitation electronics (fail safe)\"Technical drawings available on datasheet\"

CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 CHANNELS + SUM

Código: CABIN-2xB1SUMD
Valorado con 0 de 5

Código Interno:

Reference : CABIN-2xB1SUMDThe CABIN-2IB1SUMD and CABIN-2DB1SUMD are crane overload protection systems designed to manage 2 hoisting devices as well as the sum of the loads. x = input: - I: mV/V or - D: process input 4(0)...20 mAo Display of hoisted loads and input signalso Monitoring system of load cell integrity and electronics (fail safe)\"Technical drawings available on datasheet\"