TENSION AND COMPRESSION LOAD CELLS
Código Interno:
Reference : 2710-2715Universal load cells combining accuracy, sturdiness and easy installationo Material: - 2710: stainless steel - 2715: alloy steelo Protection class: IP67o Compact designo Cable length: see drawing table - CL (other lengths available on request)Technical drawings available on datasheetHIGH-CAPACITY NON-CONTACT ROTARY TORQUE SENSORS
Código Interno:
Reference : 65000General purpose, high capacity non-contact rotary torque sensors.o Bidirectionalo Measurement range up to 25 kN·m (>25 kN·m on request)o Rotating speed up to 8000 rpmo Integrated signal conditioningo Analogue output signal (see Wiring table)o Cable length: 5 mTechnical drawings available on datasheetANALOGUE INPUT LARGE PANEL METERS
Código Interno:
Reference : INDI-MAXS DISP-MAXLarge panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso 5 digits of 38 mm heighto Intuitive and easy programming (high flexibility)o 16 points scaling for linearisationo Programmable function keys/user inputso Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485, fieldbus capabilities- HOUSE-MAX- HOUSE-MAX-IP: protection class IP64FUNCTIONAL SAFETY CERTIFIED LOAD LIMITER ELECTRONICS
Código Interno:
Reference : SAFETY-BOYOverload protection electronics for hoisting devices with certification for performance level PL d according to EN ISO 13849-1.o 2 redundant channels with constant comparing of both signalso PFHd 4.29 x 10E-08o Load limiter electronics certified for functional safety up to PL d Category 3, DC: mediumo Display of hoisted load and input signalo Monitoring system of the integrity of load cells with continuous comparison of both channels and internal \"watchdog\" for the electronicso Analogue output: 2 x 4...20 mA\"Technical drawings available on datasheet\"HAND-HELD RADIO RECEIVERS WITH DISPLAY
Código Interno:
Reference : WI-T24RE-HxThe WI-T24RE-HS, WI-T24RE-HA and WI-T24RE-HR are hand-held indicators for sensors equipped with a radio transmitter.o Frequency: 2.4 GHzo Licence: exemptiono Range: up to 800 m open fieldo Antenna: integratedo High resolution: 7 digits o Channels: - WI-T24RE-HS: 1 - WI-T24RE-HA: up to 12 - WI-T24RE-HR: displays all transmitters within its range (roaming)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- leather carry case with clear viewing window and shoulder strap (CASE-PSD)CONTAINER WEIGHING SYSTEM
Código Interno:
Reference : SPREADER-BOYNew generation of electronic data logging for weighing containers during handling. This one is designed to meet the new SOLAS requirement making it mandatory for containers to be weighed before they are loaded on board ships.o 4 or 8 x 4-20 mA analogue inputs for force transducerso 4 digital inputs (start, stop and tare signal)o 2 output relay able to signal an alarm (audible, luminous warning signal, etc.)o Analogue outputs according to the measurementso Data recording on a CompactFlash memory cardo Colour touch screeno Ethernet connectiono RS-485 / PROFIBUAS interface (option)\"Technical drawings available on datasheet\"ANALOGUE INPUT PANEL METERS
Código Interno:
Reference : INDI-PAXS DISP-PAXUniversal panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputso Intuitive and easy programming (high flexibility)o 16 points scaling for linearisationo Programmable function keys/user inputso Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485, USB or fieldbus capabilities- NEMA 4X / IP65 (transparent protection cover - Option \"COVER PAX\")- Desktop or industrial steel housing- Rail DIN adaptorANALOGUE INPUT PANEL METERS WITH DUAL LINE DISPLAY
Código Interno:
Reference : INDI-PAX2S DISP-PAX2APanel meters with two display lines for Wheatstone bridge sensors or electrical analogue measurementso Dual line display 6 digits (18 mm) and 9 digits (8.9 mm)o Tricolour displayo Universal power supply (AC/DC)o Up to 160 measurements per secondo Built-in USB programming port unit configurationAVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- 2 or 4 set-points with relay outputs- RS-232, RS-485 or fieldbus capabilities- NEXMA 4X / P65 (transparent cover - Option \"COVER PAX\")- Desktop or industrial steel housing- DIN rail adaptorCRANE OVERLOAD PROTECTION ELECTRONICS
Código Interno:
Reference : INDI-BOY DISP-BOYPCrane overload protection electronics with 3 set-points and display to be installed on a front panel.o Easy and intuitive calibrationo Display of hoisted load and input signalo Internal monitoring system of load cell integrity and load limitation electronics (fail safe)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- RS-232, RS-485 or fieldbus capabilities- NEMA 4X / IP65 (transparent protection cover + Option \"COVER PAX\")- rail DIN adaptor- power supply: 48 VAC (only for 85...230 VAC version)- also available with industrial metallic housing (see CRANE-BOY and CRANE-BOYP products)DISPLAY FOR RUNNING LINE TENSIOMETERS
Código Interno:
Reference : DISP-RLT3-channel display specially designed to work in combination with SENSY running line tensiometers 5570, 5575, 5580 and 5585 for winches and running cables in order to display the tensile load, the speed and the pay-out.o Inputs: - force transducer - payout sensoro Digital displays and bar graphs: - force - speed - payouto Data transmission\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- data logging (download by USB stick or Ethernet network)- communication output RS-232, RS-485- analogue output 4 (0)...20 mA or 0...10 V- relay output 2 or 4 FORM-C (5 A, 230 VAC resistive load)- power supply: 110 & 230 VAC (50 - 60 Hz)CRANE OVERLOAD PROTECTION ELECTRONICS FOR 2 HOISTING DEVICES
Código Interno:
Reference : DISP-BOYDP CRANE-BOYDPElectronics ensuring the individual limitation of loads lifted by 2 hoisting systems and limitation of the function of these loads (sum, difference, multiplication, ratio)o Type: - DISP-BOYDP: to be installed on the front panel - CRANE-BOYDP: with industrial metallic housing o Easy and intuitive calibrationo Display of hoisted loads and input signalso Internal monitoring system of the integrity of load cells and load limitation electronics (fail safe)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- Analogue output 4 (0)...20 mA or 0...10 V- RS-232, RS-485 or fieldbus capabilities- NEMA 4X/IP65 (transparent protection cover + Option \"COVER PAX\")- rail DIN adaptor- power supply: 48 VAC (only for 85...230 VAC version)- stainless steel housingSTRAIN-GAUGE EMBEDDED DIGITAL CONVERTERS
Código Interno:
Reference :These digital converters convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USBo Very high resolutiono Linearisation of transducer signal availableo High transmission speedo Internal or external mounting depending on the size of the transducero When external, rectangular box in aluminium (protection class IP65)\"Technical drawings available on datasheet\"AVAILABLE OPTIONS- temperature measurement with compensation of thermal drifts