Mostrando 1–9 de 206 resultados

STRAIN-GAUGE EMBEDDED ANALOGUE AMPLIFIERS

Código: ????
Valorado con 0 de 5

Actualizado: 2024-01-04

These analogue amplifiers convert the signal from a Wheatstone bridge (mV/V) into a robust industrial standardised analogue signal.
o Internal or external mounting depending on the size of the transducer
o If external, cylindrical housing in nickel-plated brass (IP67) or rectangular box in aluminium (low-cost version) (IP65)
o Available version with shifted zero for bidirectional utilisation for versions 4...020 mA and 0...10 V.
o Protection against inversion of polarity
o Cable length: 0.015 m between the amplifier housing and the transducer (max. 0.5 m)

STRAIN-GAUGE EMBEDDED DIGITAL CONVERTERS

Código: ????
Valorado con 0 de 5

Actualizado: 2024-01-04

These digital converters convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB
o Very high resolution
o Linearisation of transducer signal available
o High transmission speed
o Internal or external mounting depending on the size of the transducer
o When external, rectangular box in aluminium (protection class IP65)

AVAILABLE OPTIONS- temperature measurement with compensation of thermal drifts

STRAIN-GAUGE EMBEDDED ANALOGUE AMPLIFIERS

Código: ????
Valorado con 0 de 5

Actualizado: 2024-01-04

These analogue amplifiers convert the signal from a Wheatstone bridge (mV/V) into a robust industrial standardised analogue signal.
o Internal or external mounting depending on the size of the transducer
o If external, cylindrical housing in nickel-plated brass (IP67) or rectangular box in aluminium (low-cost version) (IP65)
o Available version with shifted zero for bidirectional utilisation for versions 4...020 mA and 0...10 V.
o Protection against inversion of polarity
o Cable length: 0.015 m between the amplifier housing and the transducer (max. 0.5 m)

STRAIN-GAUGE EMBEDDED DIGITAL CONVERTERS

Código: ????
Valorado con 0 de 5

Actualizado: 2024-01-04

These digital converters convert the signal from a Wheatstone bridge (mV/V) into a standardised digital signal RS-232, RS-485 or USB
o Very high resolution
o Linearisation of transducer signal available
o High transmission speed
o Internal or external mounting depending on the size of the transducer
o When external, rectangular box in aluminium (protection class IP65)

AVAILABLE OPTIONS- temperature measurement with compensation of thermal drifts

ANALOGUE INPUT PANEL METERS

Código: INDI-PAXS DISP-PAXx
Valorado con 0 de 5

Actualizado: 2024-01-04

Universal panel meters to be used with transducers and process signalso Strain gauge, process, voltage and current inputs
o Intuitive and easy programming (high flexibility)
o 016 points scaling for linearisation
o Programmable function keys/user inputs
o Variable intensity displayAVAILABLE OPTIONS- Analogue output 4 (0)...020 mA or 0...10 V
- 2 or 4 set-points with relay outputs
- RS-232, RS-485, USB or fieldbus capabilities
- NEMA 4X / IP67 (transparent protection cover - Option \"COVER PAX\")
- Desktop or industrial steel housing
- Rail DIN adaptor

DISPLAY FOR ROTARY TORQUE SENSOR

Código: DISP-60
Valorado con 0 de 5

Actualizado: 2024-01-04

The DISP-60 is a display specially designed to be connected with a non-contact rotary torque sensor of the SENSY 60000 series.
o 1 torque sensor input 0...10 V
o 1 angle encoder input (A/B) or speed sensor input (A)
o 2 x digital input
o 2 x relay output
o USB interface (2.0 HID - Windows ® compatible software included)
o SD card slot (SD / SD HC)
o Acquisition interval: 10 ms...1 h

CONDITIONERS – AMPLIFIERS FOR STRAIN-GAUGE-BASED TRANSDUCERS

Código: COND-SGA
Valorado con 0 de 5

Actualizado: 2024-01-04

The COND-SGA conditioners - amplifiers provide standardised signals in current and voltage from every load cell, force transducer and torque sensor based on strain-gauge technology.
o Input: Wheatstone bridge 0.1 to 30 mV/V
o Output: 4(0)...020 mA, -10...0...+10 V
o Power supply:
         - COND-SGA-A: 1015...230 VAC / 018...24 VDC
         - COND-SGA-D: 018...24 VDC    
o Low-cost
o Enclosure: ABS case 0164 x 84 x 57 mm

MEASUREMENT TRANSMITTER FOR DC VOLTAGE AND CURRENT SIGNALS

Código: CONV-UI
Valorado con 0 de 5

Actualizado: 2024-01-04

Measurement transmitter designed to convert any not-normalised DC voltage or current signal into a normalised signal while providing galvanic insulation.
o Voltage or current input
o Galvanic isolation 2 kV RMS. 50 Hz during max. 60 s between input, output and power supply
o Selection of input and output ranges by jumpers behind the front plate
o Wide range of power supplies
o Rail DIN mounting
o Weight: 130 g
o Compliant with EMC EN  500082-2

JUNCTION BOXES FOR WEIGHING SYSTEMS

Código: JBOX
Valorado con 0 de 5

Actualizado: 2024-01-04

Junction boxes designed to connect several load cells in parallel to the same electronics with corner adjustment.
o 4 or 6 inputs
o Connection in 4 or 6 wires
o Cabling of load cells and electronics by screw terminals
o Waterproof