Mostrando 1–12 de 15 resultados

Single-pumping unit Series MOG

Código: Single-pumping unit Series MOG - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

hp-Single pumping unit is screwed-on or flanged design as feed or pressure modules for oil supply to TRD 411 or TRD 6004 and DIN 4755-2 must be constructed, tested, registered and labelled to test standard DIN EN 12514-1. For fuel oil supply diagram, see page 1001.
Details & Applications
Viscosity range: Motor capacities of the units are designed for:

Viscosities up to 80 cSt. for units for fuel oil EL, L
Viscosities up to 150 cSt. for units for fuel oil M, S + ES

Please ask for any differing conditions.

max. permitted underpressure: Measured on the vacuum gauge item 3 ? -0.6 bar

max. system pressure: 5 bar

Twin-pumping unit Series BIK

Código: Twin-pumping unit Series BIK - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

hp-Twin-pumping unit in screwed-on or flanged design as feed or pressure units for oil supply to TRD 411 or TRD 6004 and DIN 4755-2 must be constructed, tested, registered and labelled to test standard DIN EN 12514-1!
General specifications:
Viscosity range: Motor capacities of the units are designed for:

Viscosities up to 80 cSt. for units for fuel oil EL, L
Viscosities up to 150 cSt. for units for fuel oil M, S + ES

Please ask for any differing conditions.

max. permitted underpressure: Measured on the manometer item 3 ? -0.6 bar

max. system pressure: 5 bar

Single-pumping unit Series MOG 1900

Código: Single-pumping unit Series MOG 1900 - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

Fuel oil pressure unit with integrated bypass oil air separation for single-pipe oil supply for automatic oil burners to TRD 411 or TRD 6004 and DIN 4755 sheet 2.

Compact Twin-pumping unit Series BIKO

Código: Compact Twin-pumping unit Series BIKO - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

hp-Twin-pumping unit in screwed-on or flanged (SAE flange to DIN ISO 6162) design are used as feed or pressure unit according to TRD 411 or TRD 6004 and DIN 4755-2 must be constructed, tested, registered and labelled according to standard DIN EN 12514-1.
The BIKO series is available in 2 designs (L – light oil and S – HFO). It can optionally be used for 1- or 2-pipe system (simple conversion by the user). The selection for use a feed 1) or pressure unit is determined by the selection of pressure stages.

Small pressure accumulator unit Ölman®

Código: Small pressure accumulator unit Ölman® - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

Single unit to supply small fire places with fuel oil EL in single pipe system to DIN/EN 12514-1
The pressure is stored in the Ölman by means of spring force, which means that the reservoir is maintenance-free. The integrated filter in the suction line prevents damage to the entire system.

The control of the Ölman reliably records all relevant operating states and switches off automatically in the event of a malfunction.
The Ölman offers you reliable and sustainable production of your oils!

Single suction and pressure pump unit Series ESD

Código: Single suction and pressure pump unit Series ESD - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

The suction and pressure units are a combination of the proven hp-Pressure units with hp-High capacity suction units to handle more difficult heating oil transfer problems.
The suction units can handle underpressures up to -0.9 bar, which is 9 m geodetic height or even up to 200 m suction pipe length. With the pressure unit, loads that are further away, with observable pipe flow, can be provided in single and two-pipe operation.

Single pressure accumulator units Series DSK 4.1

Código: Single pressure accumulator units Series DSK 4.1 - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

Single pressure accumulator DSK 4.1
The DSK 4.1 is used to supply oil to smaller fireplaces with EL heating oil in accordance with DIN / EN 12514-1. All units are built, checked, registered and marked according to this test standard.
With pressure accumulator control system
The DSK 4.1 series with pressure accumulator control is used for single-line oil supply in accordance with DIN / EN 12514-1 for automatic oil burners. Feeder unit built, tested, registered and marked according to DIN / EN 12514-1!

Saugfix GPS-10 Suction Unit

Código: Saugfix GPS-10 Suction Unit - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

The series GPS-10 “Saugfix” suction unit is used to supply oil to fireplaces with EL heating oil (kerosene) in accordance with DIN 12514-1.
Details and applications:

high-performance suction unit to independently control oil supply for single-line burners with safety shutdown
Designed for small withdrawal quantities. It complements the proven hp high-performance suction units of the HSPE series
The unit is delivered complete with an oil pan and leakage oil detector

High-capacity single suction aggregates

Código: High-capacity single suction aggregates - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

Single units HSPE series
This hp oil supply is for fireplaces that are far or high from the storage tank. The suction units can handle underpressures up to -0.9 bar, which is 9 m geodetic height or even up to 200 m suction pipe length.

High-capacity double suction aggregates

Código: High-capacity double suction aggregates - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

hp-Double unit HSPD series
This hp-Oil supply is for fire places with heating oil EL to DIN/EN 12514-1.

Double pressure accumulator units Series DSK 2.16

Código: Double pressure accumulator units Series DSK 2.16 - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

Double wall-mounted unit with pressure accumulator control system for automatic alternating current and fault changeover

Details and applications:

With hp-Internal gear pump fitted horizontally on the oil pan with overflow valve and all the required fittings
Supplied complete with leakage detector

Continuous extraction: l/h fuel oil EL
discharge height:           m
Voltage:                            Volt, 50 Hz

Air-separation unit diagram I & III

Código: Air-separation unit diagram I & III - HP TECHNIK
Valorado con 0 de 5

Actualizado: 2024-01-04

For single-pipe installation of the burner for supply pressure max. 10 bar, with pressure regulator set to 0.5 bar
Details and applications:

Filter with ball valve and filter cup (brass)
Adapter for oil meter
Solenoid valve for burner control system
Pressure regulator set fixed at secondary pressure 0.5 bar, system pressure max. 10 bar
Air-separation vessel with ball valve for manometer and
Automatic air vent for starting up
Pressure-equalising fitting, for increase in volume due to heating up
Completely fitted in oil pan for floor or wall fitting,
direction of flow may be left or right