The EDGE FLOW SENSOR
Actualizado: 2024-01-04
Key featuresAnalog Output Signal:
4-20mA and 0-10V
Excellent Linearity:
10-point linearization table available through Bluetooth app
Analog Output Resolution:
16 bit
Advanced Features through PC Toolkit and Mobile App:
Additional ouputs (0-5V, 1-5V, 1-10V and 2-10V), Linearization tables, Wireless flow monitor with mobile app
Bluetooth (Optional):
Enabled for wireless setup from a mobile device
RT-50 Battery-Powered Flow Rate Transmitter
Actualizado: 2024-01-04
Key featuresInput Options:
Inductive and Carrier frequency sensors
Power Source:
3.6V “C” cell battery, field replaceable: 3 year continuous use estimated average life, depending on options enabled
Flow Meter Compatibility:
JV series positive displacement gear meters and TRG, TR and TW turbine meters.
Temperature Rating:
-4 to 140°F (-20 to 60°C) ambient, 175?F (80?C) maximum fluid temperature
HUB-40 Flow Sensor
Actualizado: 2024-01-04
Key featuresSupply Voltage:
10-24 VDC
Supply Current:
8 mA @ 12 VDC, 12 mA @ VDC
Sensor/Monitor Frequency Output:
Flow Dependent, 0.5 Hz minimum
Output Ampliture:
VHIGH = VSUPPLY - 0.7 Volts, VLOW = 0 Volts
Duty Signal:
50% ± 15%
Temperature Ratings:
-20 to 85°C (-4 to 140°F)
FAC-R FREQUENCY TO ANALOG CONVERTER
Actualizado: 2024-01-04
Key featuresFull Input Frequency Range:
0.25Hz to 5,000Hz
Supply Voltage Rate:
10-28Vdc
Analog Output Resolution:
16 bit
Advanced Features through PC Toolkit and Mobile App::
Additional ouputs (0-5V, 1-5V, 1-10V and 2-10V), Linearization tables, Wireless flow monitor with mobile app
Bluetooth (Optional):
Enabled for wireless setup from a mobile device
CAPM-15 High Temperature Sensor System
Actualizado: 2024-01-04
Key featuresMeter Compatibility:
Used with JV-CG and JV-KG gear meters (not for use with aluminum meters)
Pickup System:
Includes CAPM-15/AMP signal amplifier module and the CP-30 high temperature carrier frequency sensor
Temperature Rating:
Safe for medium temperatures up to 400°F
Supply Voltage:
Between 10 and 30 VDC
Protection:
Protected against reversed polarity on the voltage supply
CAPM-2 Carrier Frequency Sensor
Actualizado: 2024-01-04
Key featuresMeter Compatibility:
Used with JV-CG and JV-KG meters (not for use with aluminum meters)
Output Signal:
Square wave, voltage pulse of approximate aplitude (supply - 1.5V)
Sourcing Output:
PNP type sourcing open collector transistor
Intrinsically Safe:
Intrinsically safe CAPM-2o version available
IS Safe Version:
UL & cUL certified for use in Class 1, Div 1 locations
CAPM-3 Carrier Frequency Sensor
Actualizado: 2024-01-04
Key featuresMeter Compatibility:
Used with HPM-SLG and JVS-SLG gear meters
Output Signal:
Square wave, voltage pulse of approximate aplitude (supply - 1.5V)
Sourcing output:
PNP type sourcing open collector transistor
Intrinsically Safe:
Intrinsically safe CAPM-3o version available
IS Safe Version:
UL & cUL certified for use in Class 1, Div 1 locations