The EDGE FLOW SENSOR

Código: The EDGE FLOW SENSOR - Aw Lake

Actualizado: 2024-01-04

Key features

Analog Output Signal:
4-20mA and 0-10V

Excellent Linearity:
10-point linearization table available through Bluetooth app

Analog Output Resolution:
16 bit

Advanced Features through PC Toolkit and Mobile App:
Additional ouputs (0-5V, 1-5V, 1-10V and 2-10V), Linearization tables, Wireless flow monitor with mobile app

Bluetooth (Optional):
Enabled for wireless setup from a mobile device

RT-50 Battery-Powered Flow Rate Transmitter

Código: RT-50 Battery-Powered Flow Rate Transmitter - Aw Lake

Actualizado: 2024-01-04

Key features

Input Options:
Inductive and Carrier frequency sensors

Power Source:
3.6V “C” cell battery, field replaceable: 3 year continuous use estimated average life, depending on options enabled

Flow Meter Compatibility:
JV series positive displacement gear meters and TRG, TR and TW turbine meters.

Temperature Rating:
-4 to 140°F (-20 to 60°C) ambient, 175?F (80?C) maximum fluid temperature

RT-30 Flow Transmitter – EX & non-EX

Código: RT-30 Flow Transmitter – EX & non-EX - Aw Lake

Actualizado: 2024-01-04

Key features


Hazardous Area Certifications:
CSA (US & Canada), IECEx or ATEX

Communication Protocol:
HART option for remote monitoring & programming

Supply Voltage:
10-24 VDC

Temperature Rating:
-20 to 60°C (-4 to 140°F)

HUB-40EX Hazardous Area Flow Sensor

Código: HUB-40EX Hazardous Area Flow Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Hazardous Area Certifications:
CSA (US & Canada) or IECEx / ATEX

Output Signal:
Square wave with a duty cycle of approximately 50%

Supply Voltage:
10-24 VDC

Temperature Rating:
-4 to 140°F (-20 to 60°C)

HUB-40 Flow Sensor

Código: HUB-40 Flow Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Supply Voltage:
10-24 VDC

Supply Current:
8 mA @ 12 VDC, 12 mA @ VDC

Sensor/Monitor Frequency Output:
Flow Dependent, 0.5 Hz minimum

Output Ampliture:
VHIGH = VSUPPLY - 0.7 Volts, VLOW = 0 Volts

Duty Signal:
50% ± 15%

Temperature Ratings:
-20 to 85°C (-4 to 140°F)

MX-9000 Panel Mount Process Monitor

Código: MX-9000 Panel Mount Process Monitor - Aw Lake

Actualizado: 2024-01-04

Key features

Flow Display Options:
Rate, total, limit, and ratio


Channels:
Single or dual channel

Output Options:
Programmable Form C relay and 4-20 mA

FAC-R FREQUENCY TO ANALOG CONVERTER

Código: FAC-R FREQUENCY TO ANALOG CONVERTER - Aw Lake

Actualizado: 2024-01-04

Key features

Full Input Frequency Range:
0.25Hz to 5,000Hz

Supply Voltage Rate:
10-28Vdc

Analog Output Resolution:
16 bit

Advanced Features through PC Toolkit and Mobile App::
Additional ouputs (0-5V, 1-5V, 1-10V and 2-10V), Linearization tables, Wireless flow monitor with mobile app


Bluetooth (Optional):
Enabled for wireless setup from a mobile device

CAPM-15 High Temperature Sensor System

Código: CAPM-15 High Temperature Sensor System - Aw Lake

Actualizado: 2024-01-04

Key features

Meter Compatibility:
Used with JV-CG and JV-KG gear meters (not for use with aluminum meters)

Pickup System:
Includes CAPM-15/AMP signal amplifier module and the CP-30 high temperature carrier frequency sensor


Temperature Rating:
Safe for medium temperatures up to 400°F


Supply Voltage:
Between 10 and 30 VDC

Protection:
Protected against reversed polarity on the voltage supply

CAPM-2 Carrier Frequency Sensor

Código: CAPM-2 Carrier Frequency Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Meter Compatibility:
Used with JV-CG and JV-KG meters (not for use with aluminum meters)

Output Signal:
Square wave, voltage pulse of approximate aplitude (supply - 1.5V)

Sourcing Output:
PNP type sourcing open collector transistor


Intrinsically Safe:
Intrinsically safe CAPM-2o version available


IS Safe Version:
UL & cUL certified for use in Class 1, Div 1 locations

CAPM-3 Carrier Frequency Sensor

Código: CAPM-3 Carrier Frequency Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Meter Compatibility:
Used with HPM-SLG and JVS-SLG gear meters

Output Signal:
Square wave, voltage pulse of approximate aplitude (supply - 1.5V)

Sourcing output:
PNP type sourcing open collector transistor

Intrinsically Safe:
Intrinsically safe CAPM-3o version available


IS Safe Version:
UL & cUL certified for use in Class 1, Div 1 locations

FOP-20 Fiber Optic Sensor

Código: FOP-20 Fiber Optic Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Meter Compatibility:
Used with JV-CG and JV-KG meters

System Includes:
Meter mounted reluctance pickup with a fiber optic transmitter, fiber optic cable and OPTV-20 fiber optic receiver

Four cable lengths:
30\', 45\', 60\' and 100\'

FOP-30 Fiber Optic Sensor

Código: FOP-30 Fiber Optic Sensor - Aw Lake

Actualizado: 2024-01-04

Key features

Meter Compatibility:
Used with SLG gear meters

Certification:
UL certified