Mostrando 1–12 de 104 resultados

Calcium Calibration Kit

Código: 2120XPCAL
Valorado con 0 de 5

Código Interno: PRO3938

Actualizado: 2024-02-28

Calibration Kit
Includes:
* Carrying case
* 0.5 mL pipette (204847-001)
* Box of pipette tips (204846-001)
* Wash bottle,
* (1) x 2 oz bottle calcium standard 1 (191 ppm)
* (1) x 2 oz bottle calcium standard 2 (1920 ppm) and
* (1) inlet filter

Calcium Hardness Analyzer With Protective Enclosure 25 ppb to 500 ppm + Calcium hardness analyzer wi

Código: 2120XPEN
Valorado con 0 de 5

Código Interno: PRO12886

Actualizado: 2024-02-28

Calcium Hardness Analyzer With Protective Enclosure
Range: 25 ppb to 500 ppm
Sample Conditions:
• Temperature: 5 to 35 C
• Inlet Pressure: 8 to 100 Psi
• Total Alkalinity: Less Than 250 ppm CaCO3
• Rate Flow: 40 mL/min

Orion 2120XP Calcium HardnessMonitor

Código: 212050XPF
Valorado con 0 de 5

Código Interno: PRO5381

Actualizado: 2024-02-28

CONSUMABLE KIT FOR 01 YEAR OPERATION
Reagent-less Calcium Hardness Consumables Kit
(Orion 2120XP Calcium HardnessMonitor)
Contains everything it is needed to operate the analyzer for 1 year
* (6) 1Lt empty bottles for use with acid reagent

Multi-Input Intelligent Process Analyzer Controls up to 4 parameter with 4-20mA output , Dissolved O

Código: AP5XXXK(Trans-DO)
Valorado con 0 de 5

Código Interno: PRO3759

Actualizado: 2024-01-03

AQUAPRO (AP5XXXK)
Multi-Input Intelligent Process Analyzer
* Controls up to 4 parameter with 4-20mA output for each one.
* Display all 4 parameter in just one screen
* Chanel 1:Dissolved Oxygen (PPM)
* Chanel 2: Empty Chanel
* Chanel 3: Empty Chanel
* Chanel 4: Empty Chanel

long diffusion tubing and O-rings

Código: 181060
Valorado con 0 de 5

Código Interno: PRO5492

Actualizado: 2023-12-11

Difusion tubing and O-ring KIT for Orion 2117LL Low-Level Chloride Analyzer
Consisting of:
* (4) x 2 ft long diffusion tubing and O-rings

Syringe kit for use with dynamic calibrator during

Código: 180096
Valorado con 0 de 5

Código Interno: PRO24907

Actualizado: 2023-12-11

Syringe kit with 20 cc syringe for use with dynamic calibrator during three-point calibration on 2117LL

Restrictor tube assembly

Código: 2100RT
Valorado con 0 de 5

Código Interno: PRO24908

Actualizado: 2023-12-11

2100RT
Restrictor tube assembly
Chloride Analyzer

100 ppm chloride standard

Código: 941707
Valorado con 0 de 5

Código Interno: PRO12644

Actualizado: 2023-12-11

100 ppm chloride standard, 1 pint (475mL) bot tle
Thermo Scientific

Chloride Electrode Kit

Código: 2117XPEK
Valorado con 0 de 5

Código Interno: PRO11674

Actualizado: 2023-12-11

Chloride Electrode Kit
Includes:
• Chloride electrode (100025)
• Reference electrode (100057) and
• (1) x 4oz bottle reference electrode filling solution (100057F4)

ORION Main Tubing Kit , Analizador de Silice

Código: 2230TK
Valorado con 0 de 5

Código Interno: PRO12283

Actualizado: 2023-11-23

Kit completo de Tuberias Principales para Reagentes, Standard y muestras

ORION Maintenance Kit

Código: 2230MK
Valorado con 0 de 5

Código Interno: PRO2761

Actualizado: 2023-11-23

2230MK
• Kit de mantenimiento con Tubing de Arnés (Para bombas peristálticas) y su respectivo lubricante)

AQUACLEAR Low Range Turbidity 0 to 200 NTU, Output: 2×4-20mA;100-240Vac

Código: AQT1DO(Turbidity)
Valorado con 0 de 5

Código Interno: PRO3761

Actualizado: 2023-11-22

AQT1DO
AQUACLEAR Low Range Turbidity
* Range: 0 to 200 NTU
* Resolution: 0.001 NTU
* Accuracy : +/- 2% of reading
* Flow Rate: Between (250 to 500 mL/min)
* Water Temperature range: -5 to 50 C
* Air Temperature Range: -5 to 60 C
* Power Source: 24Vdc or 100-240 VAC